Mouse dorsal CA1 imaging during multisensory stimulation

CA1 imaging across light, auditory, and mixed stimulus blocks alongside linear track running.
Extracted from full textTranscribed by a curator from the published methods section. Values not stated in the paper are marked as not reported rather than inferred.
Animal
Species
Mouse
Strain
C57BL/6J
Sex
Male
Age at surgery
10-12 weeks
Animals
20
Target
Brain region
Coordinates
Injection AP -2.1, ML +2.1, DV -1.7; craniotomy AP -2.1, ML 1.6; lens to DV -1.35 from skull top
Hemisphere
Right
Cell type
CA1 pyramidal neurons
Indicator
Indicator
GCaMP6f
Reports
Calcium
Delivery
AAV injection
Construct
pAAV.Syn.GCaMP6f.WPRE.SV40
Titer
2.2 x 10^13 GC/mL
Injection volume
500 nL
Expression time
5 weeks
Optical access
Method
GRIN lens
Lens
0.23 pitch (Edmund Optics 64-519), through a 2 mm craniotomy
Implant depth
-1.35 mm from skull top
Surgery staging
Separate surgeries
Injection to implant
1 week
Implant to baseplating
5 weeks
Imaging
Condition
Freely behaving
Frame rate
30 fps
Behavior
Linear track, Light stimuli (2 s on / 3-3.5 s off; 300 trials), Auditory stimuli (4/8/16 kHz; 100 trials each), Mixed light-sound stimuli
Analysis
CNMF-E, NoRMCorre, OASIS, MATLAB 2019a, Python 3.7
Who to ask
Experimenter
Chris French
Institution
The University of Melbourne
Notes
Five animals per experiment across four experiments.